Scrollpump Complete Product Model List

WX 0080H 干式涡旋真空泵

WX 0080H 干式涡旋真空泵

电机功率2.20 Kw
极限真空1.0 Pa
额定电压△200-240V/Y345-415V
额定流量80 m3/h
Inquiry / unit
WX 0040H 干式涡旋真空泵

WX 0040H 干式涡旋真空泵

电机功率1.50 Kw
极限真空5.0 Pa
额定电压△200-240V/Y345-415V
额定流量40 m3/h
Inquiry / unit
WX 0020H 干式涡旋真空泵

WX 0020H 干式涡旋真空泵

电机功率0.75 Kw
极限真空5.0 Pa
额定电压△200-240V/Y345-415V
额定流量20 m3/h
Inquiry / unit

Common Challenges in Precision Vacuum Working Conditions

Pump Oil Backflow Contaminates the Chamber, Causing Precision Process Failure

Oil vapor backflow from oil-lubricated vacuum pumps contaminates the instrument chamber, causing test distortion and scrapping of coated products.

High Noise and Vibration, Not Suitable for Built-in Instrument Cabinets

Traditional pumps have high noise and vibration, which interfere with instruments and operators when placed in laboratories or integrated into equipment cabinets.

Shaft Seal Wear and Leakage, Process Gas Escape

Rotating shaft seals are prone to wear, causing media to leak outward, unstable vacuum degree, and inability to recover rare gases.

Complicated Maintenance, Must Return to Factory for Disassembly, Long Downtime

Replacement of wearing parts requires returning to the factory for disassembly, resulting in a long equipment downtime cycle and affecting the experimental progress of precision instrument production lines.

Core Advantages of Leynow WX Dry Scroll Vacuum Pump

Single-sided Scroll, Dry and Oil-free, Fully Sealed without Shaft Seals

Non-contact dry compression between fixed and orbiting scrolls; metal bellows static sealing, no rotating shaft seal, completely preventing process medium leakage and contamination.

Low Noise and Low Vibration, Suitable for Cabinet Integration

Continuous and smooth scroll compression, small gas pulsation; optimized dynamic balance of the whole machine, low noise and vibration, suitable for laboratories and built-in instruments.

Virtually Maintenance-free, On-site Seal Replacement

Long-life lubricated bearings; maintenance only requires replacing the scroll tip seal without special tools, completed by the operator on-site without returning to the factory for disassembly.

Ideal Dry Backing Pump for Molecular Pumps and Helium Leak Detectors

Excellent performance in the medium vacuum range, oil-free and does not contaminate the chamber, suitable for complete high-vacuum systems of turbo molecular pumps and helium mass spectrometer leak detectors.

Multiple Models and Specifications, Can Be Embedded in Complete Equipment

Full WX0020H/WX0040H/WX0080H series, available as standalone machines or as built-in vacuum sources for equipment.

Original Factory Parts, Technical Support for Precision Working Conditions

Scroll tip seals and filters in stock from the original factory; mature experience in leak detection and gas recovery, full support for selection, troubleshooting, and factory repair and maintenance.

Product Specifications & Parameters

Product Model Motor Power Ultimate Vacuum Rated Voltage Rated Flow Rated Current Industry Application

WX 0020H

0.75 Kw 5.0 Pa △200-240V/Y345-415V 20 m3/h 3.8△/2.2Y 真空镀膜

WX 0040H

1.50 Kw 5.0 Pa △200-240V/Y345-415V 40 m3/h 7.5△/4.3Y 真空镀膜
Working Principle of Leynow WX Dry Scroll Vacuum Pump
  • The WX dry scroll vacuum pump is based on single-sided scroll technology, integrating dry compression with a fully enclosed structure. The pump body consists of a fixed scroll and an orbiting scroll.

  • The motor drives the orbiting scroll to perform eccentric revolution, and the orbiting scroll moves along the internal track of the fixed scroll; continuously forming, moving, and shrinking crescent-shaped compression chambers; gas is drawn in from the inlet, compressed through the scroll chambers, and discharged from the central exhaust port.

  • Metal bellows static sealing, no rotating shaft seal, preventing process gas leakage; long-life lubricated bearings; maintenance only requires replacing the scroll tip seal without special tools, which can be done by the operator on-site.

  • The entire machine has low noise and low vibration, and is a well-proven dry vacuum solution for medium vacuum analytical instruments and scientific equipment.

Applicable Industries and Typical Processes

Leynow WX dry scroll vacuum pump, dry and oil-free, low noise and low vibration, oriented towards precision medium vacuum scenarios, widely used in clean processes such as instruments, semiconductors, and gas recovery.

  • The scroll vacuum pump adopts single-sided scroll dry compression and a fully sealed shaft-seal-free structure, outputting clean medium vacuum and operating virtually maintenance-free.

  • Suitable for helium leak detection, molecular pump backing pre-pumping, rare gas recovery, and precision sample processing. It can be used as a standalone machine or embedded in complete equipment as a built-in vacuum source.

Technical Information & Materials

Compiled technical reference materials related to vacuum pumps for selection, equipment commissioning, and troubleshooting.

Project Selection Reference Suggestions
  • Confirm core indicators: required ultimate vacuum, actual pumping volume;
  • Clarify the extracted medium: water vapor, dust, corrosive gases, etc., to determine whether filtration, condensation, or explosion-proofing is needed;
  • Confirm the usage environment: indoor/outdoor, on ships, high temperature and humidity, dust environment;
  • Usage mode: intermittent use or long-term continuous operation;
  • Standalone equipment or a complete central vacuum station.

Applicable Industries and Typical Processes

Applicable Industries
Semiconductors and Photovoltaics

Semiconductors and Photovoltaics

Wafer transfer, coating, and etching processes require clean vacuum; dry oil-free avoids oil contamination.

Vacuum Coating Industry

Vacuum Coating Industry

PVD/CVD and optical coating require high cleanliness; scroll pumps provide stable backing pumping.

Lithium Battery New Energy

Lithium Battery New Energy

Processes such as electrolyte filling, drying, and packaging avoid oil; scroll vacuum pumps ensure cell quality.

Pharmaceuticals and Biology

Pharmaceuticals and Biology

Freeze-drying, aseptic packaging, and laboratory filtration require oil-free clean vacuum, compliant with GMP.

Food Vacuum Packaging

Food Vacuum Packaging

Vacuum sealing and modified atmosphere packaging; oil-free pumps prevent oil mist from contaminating food.

Optics and Electronics Manufacturing

Optics and Electronics Manufacturing

Lens coating and electronic component adsorption handling; clean vacuum improves yield.

Scientific Research Laboratory

Scientific Research Laboratory

Analytical instruments, molecular pump backing, and vacuum experiments; low noise and oil-free stable operation.

Environmental Testing

Environmental Testing

Gas sampling, vacuum degassing, and leak detection analysis; clean vacuum ensures accurate data.

Typical Processes
Vacuum Coating

Vacuum Coating

Providing clean backing vacuum for PVD/CVD, sputtering, and evaporation, avoiding oil contamination of the film layer.

Vacuum Adsorption Handling

Vacuum Adsorption Handling

Adsorption and handling of semiconductors, glass, and lithium battery electrodes: fast response, stable vacuum, and no damage to workpieces.

Vacuum Packaging

Vacuum Packaging

Vacuum sealing of food, pharmaceuticals, and electronic components; oil-free and clean, extending shelf life.

Freeze-drying

Freeze-drying

Pre-freeze-drying vacuum pumping for pharmaceuticals and food; oil-free scroll pumps with cold traps ensure product activity.

Molecular Pump Backing

Molecular Pump Backing

Two-stage scroll pumps as molecular pump backing: high ultimate vacuum, low vibration, and low oil backflow.

Vacuum Leak Detection

Vacuum Leak Detection

Leak detection for pipelines, containers, and seals; stable pumping speed helps quickly reach detection vacuum.

Vacuum Defoaming / Degassing

Vacuum Defoaming / Degassing

Defoaming of glue, resin, and liquids; oil-free and clean, does not affect material properties.

Vacuum Drying / Impregnation

Vacuum Drying / Impregnation

Vacuum drying and impregnation of electronic components, transformers, and materials; thorough degassing without oil contamination.

  • Usage Limitations: Scroll vacuum pumps are not suitable for extracting large amounts of dust, highly corrosive media, or large amounts of condensable water vapor; a filter is recommended at the front end to protect the pump chamber; do not extract high-concentration oxygen media.

  • Selection Recommendations: For precision instruments, helium leak detection, and molecular pump backing, prioritize scroll vacuum pumps; for rough vacuum adsorption scenarios, oil-free carbon vane rotary vane vacuum pumps can be selected.

Customer FAQs

What is the difference between a scroll vacuum pump and an oil-free carbon vane rotary vane pump?

Scroll pumps have non-contact fixed and orbiting scrolls, no carbon vane consumables, lower vibration and noise, fully sealed with no shaft seal leakage, and are more suitable for precision instrument leak detection and molecular pump backing; carbon vane rotary vane pumps rely on graphite carbon vane friction, and carbon vanes are consumables, making them more suitable for rough vacuum conditions such as CNC and packaging adsorption.

Can a scroll pump be used directly as a backing pump for a molecular pump?

The WX series dry scroll pump is an ideal dry backing pump for turbo molecular pumps. It is oil-free and will not contaminate the molecular pump and chamber, and is widely used in high vacuum analytical equipment.

Does "almost maintenance-free" mean no maintenance is required at all?

No; the main maintenance point is the scroll tip seal, which can be replaced on-site without returning to the factory; regularly check the intake filter; bearings are long-life lubricated, and periodic inspections are sufficient.

Is the scroll pump suitable for helium leak detection and rare gas recovery?

Highly suitable, fully static sealing with no shaft seal leakage; the pump chamber is dry and oil-free, will not contaminate helium and various rare gases, ensuring the purity of recovered gas.

Can you provide seal accessories and repair services?

Complete original factory scroll tip seals and intake filter accessories; providing technical consultation, troubleshooting, and factory repair and maintenance.

Do you have any questions about vacuum pump systems and solutions?

Please fill in your requirements carefully, and we will contact you within 24 hours.

Products
Oil-free Vacuum Pump Rotary Vacuum Pump Dry Vacuum Pump Roots Vacuum Pump Oilless Compressor Side Channel Blower