Oil vapor backflow from oil-lubricated vacuum pumps contaminates the instrument chamber, causing test distortion and scrapping of coated products.
Traditional pumps have high noise and vibration, which interfere with instruments and operators when placed in laboratories or integrated into equipment cabinets.
Rotating shaft seals are prone to wear, causing media to leak outward, unstable vacuum degree, and inability to recover rare gases.
Replacement of wearing parts requires returning to the factory for disassembly, resulting in a long equipment downtime cycle and affecting the experimental progress of precision instrument production lines.
Non-contact dry compression between fixed and orbiting scrolls; metal bellows static sealing, no rotating shaft seal, completely preventing process medium leakage and contamination.
Continuous and smooth scroll compression, small gas pulsation; optimized dynamic balance of the whole machine, low noise and vibration, suitable for laboratories and built-in instruments.
Long-life lubricated bearings; maintenance only requires replacing the scroll tip seal without special tools, completed by the operator on-site without returning to the factory for disassembly.
Excellent performance in the medium vacuum range, oil-free and does not contaminate the chamber, suitable for complete high-vacuum systems of turbo molecular pumps and helium mass spectrometer leak detectors.
Full WX0020H/WX0040H/WX0080H series, available as standalone machines or as built-in vacuum sources for equipment.
Scroll tip seals and filters in stock from the original factory; mature experience in leak detection and gas recovery, full support for selection, troubleshooting, and factory repair and maintenance.
| Product Model | Motor Power | Ultimate Vacuum | Rated Voltage | Rated Flow | Rated Current | Industry Application |
|---|---|---|---|---|---|---|
WX 0020H |
0.75 Kw | 5.0 Pa | △200-240V/Y345-415V | 20 m3/h | 3.8△/2.2Y | 真空镀膜 |
WX 0040H |
1.50 Kw | 5.0 Pa | △200-240V/Y345-415V | 40 m3/h | 7.5△/4.3Y | 真空镀膜 |
The WX dry scroll vacuum pump is based on single-sided scroll technology, integrating dry compression with a fully enclosed structure. The pump body consists of a fixed scroll and an orbiting scroll.
The motor drives the orbiting scroll to perform eccentric revolution, and the orbiting scroll moves along the internal track of the fixed scroll; continuously forming, moving, and shrinking crescent-shaped compression chambers; gas is drawn in from the inlet, compressed through the scroll chambers, and discharged from the central exhaust port.
Metal bellows static sealing, no rotating shaft seal, preventing process gas leakage; long-life lubricated bearings; maintenance only requires replacing the scroll tip seal without special tools, which can be done by the operator on-site.
The entire machine has low noise and low vibration, and is a well-proven dry vacuum solution for medium vacuum analytical instruments and scientific equipment.
Leynow WX dry scroll vacuum pump, dry and oil-free, low noise and low vibration, oriented towards precision medium vacuum scenarios, widely used in clean processes such as instruments, semiconductors, and gas recovery.
The scroll vacuum pump adopts single-sided scroll dry compression and a fully sealed shaft-seal-free structure, outputting clean medium vacuum and operating virtually maintenance-free.
Suitable for helium leak detection, molecular pump backing pre-pumping, rare gas recovery, and precision sample processing. It can be used as a standalone machine or embedded in complete equipment as a built-in vacuum source.
Compiled technical reference materials related to vacuum pumps for selection, equipment commissioning, and troubleshooting.

Wafer transfer, coating, and etching processes require clean vacuum; dry oil-free avoids oil contamination.

PVD/CVD and optical coating require high cleanliness; scroll pumps provide stable backing pumping.

Processes such as electrolyte filling, drying, and packaging avoid oil; scroll vacuum pumps ensure cell quality.

Freeze-drying, aseptic packaging, and laboratory filtration require oil-free clean vacuum, compliant with GMP.

Vacuum sealing and modified atmosphere packaging; oil-free pumps prevent oil mist from contaminating food.

Lens coating and electronic component adsorption handling; clean vacuum improves yield.

Analytical instruments, molecular pump backing, and vacuum experiments; low noise and oil-free stable operation.

Gas sampling, vacuum degassing, and leak detection analysis; clean vacuum ensures accurate data.

Providing clean backing vacuum for PVD/CVD, sputtering, and evaporation, avoiding oil contamination of the film layer.

Adsorption and handling of semiconductors, glass, and lithium battery electrodes: fast response, stable vacuum, and no damage to workpieces.

Vacuum sealing of food, pharmaceuticals, and electronic components; oil-free and clean, extending shelf life.

Pre-freeze-drying vacuum pumping for pharmaceuticals and food; oil-free scroll pumps with cold traps ensure product activity.

Two-stage scroll pumps as molecular pump backing: high ultimate vacuum, low vibration, and low oil backflow.

Leak detection for pipelines, containers, and seals; stable pumping speed helps quickly reach detection vacuum.

Defoaming of glue, resin, and liquids; oil-free and clean, does not affect material properties.

Vacuum drying and impregnation of electronic components, transformers, and materials; thorough degassing without oil contamination.
Usage Limitations: Scroll vacuum pumps are not suitable for extracting large amounts of dust, highly corrosive media, or large amounts of condensable water vapor; a filter is recommended at the front end to protect the pump chamber; do not extract high-concentration oxygen media.
Selection Recommendations: For precision instruments, helium leak detection, and molecular pump backing, prioritize scroll vacuum pumps; for rough vacuum adsorption scenarios, oil-free carbon vane rotary vane vacuum pumps can be selected.
Scroll pumps have non-contact fixed and orbiting scrolls, no carbon vane consumables, lower vibration and noise, fully sealed with no shaft seal leakage, and are more suitable for precision instrument leak detection and molecular pump backing; carbon vane rotary vane pumps rely on graphite carbon vane friction, and carbon vanes are consumables, making them more suitable for rough vacuum conditions such as CNC and packaging adsorption.
The WX series dry scroll pump is an ideal dry backing pump for turbo molecular pumps. It is oil-free and will not contaminate the molecular pump and chamber, and is widely used in high vacuum analytical equipment.
No; the main maintenance point is the scroll tip seal, which can be replaced on-site without returning to the factory; regularly check the intake filter; bearings are long-life lubricated, and periodic inspections are sufficient.
Highly suitable, fully static sealing with no shaft seal leakage; the pump chamber is dry and oil-free, will not contaminate helium and various rare gases, ensuring the purity of recovered gas.
Complete original factory scroll tip seals and intake filter accessories; providing technical consultation, troubleshooting, and factory repair and maintenance.
Please fill in your requirements carefully, and we will contact you within 24 hours.