旋片式真空泵可以抽除密封容器中的干燥气体,若附有气镇装置,还可以抽除一定量的可凝性气体。但它不适于抽除含氧过高的,对金属有腐蚀性的、对泵油会起化学反应以及含有颗粒尘埃的气体。日常使用中也会碰到各种故障,下面介绍旋片真空泵达不到规定的极限压力。
旋片真空泵达不到规定的极限压力产生原因:
1.泵油中有可凝物或气体;
2.测量方法或仪器不正确;
3.用错油或油被污染;
4.油封渗漏;
5.管路密封不严密;
6.油箱内油量不足;
7.进气口滤网堵塞;
8.进气管道过长或过窄;
9.叶片卡住或严重磨损;
10.泵体磨损;
11.“O”形圈变形老化;
12.吸气阀失效。
解决方法:
1.封闭进气口运转60分钟;
2.使用正确的测量方法或仪器;
3.换规定的新油;
4.调换油封;
5.检查管路连接处密封情况清除泄漏;
6.检查油位;
7.清洁进气口滤网;
8.使用粗而短的进气管道;
9.调换叶片;
10.送生产厂家修复或更换;
11.调换“O”型密封圈;
12.检查吸气阀动作是否灵活。